Term · Topic
Phasor Measurement Unit (PMU)
Phasor measurement unit is a time-synchronized measurement device in electric power systems that captures voltage and current phasors, frequency, and related quantities, enabling wide-area monitoring, control, and analysis that rely on precise, geographically distributed grid visibility for reliable operations and planning.
What this term record gives an agent
Vendors describe the same technology in different words. This record pins down what "PMU" means and ties it to the companies and coverage that use it, so an agent compares like with like.
One definition
A plain definition plus how it's used, what it's often confused with and why it matters.
Neighboring terms
Related terms in the same glossary, so an agent can widen or narrow a search the way the market does.
Get this term
The same record, four ways in. No key needed to try it.
MCP
curl -X POST https://mcp.decisioninsights.ai/api/mcp-public \
-H "content-type: application/json" \
-H "accept: application/json, text/event-stream" \
-d '{"id":1,"jsonrpc":"2.0","method":"tools/call","params":{"arguments":{"slug":"phasor-measurement-unit-pmu"},"name":"di_get_term"}}'REST
GET https://api.decisioninsights.ai/api/public/v1/glossary/73c585fa-43f3-442a-9327-d7dffb3c1e14CLI
di get-glossary --slug phasor-measurement-unit-pmuJSON-LD
The schema.org markup this page publishes for search engines and AI agents, exactly as they read it.
[
{
"@context": "https://schema.org",
"@id": "https://decisioninsights.ai/#website",
"@type": "WebSite",
"name": "Decision Insights",
"potentialAction": {
"@type": "SearchAction",
"target": {
"@type": "EntryPoint",
"urlTemplate": "https://decisioninsights.ai/search/?q={search_term_string}&submit=1"
}
},
"publisher": {
"@id": "https://decisioninsights.ai/#organization"
},
"url": "https://decisioninsights.ai"
},
{
"@context": "https://schema.org",
"@id": "https://decisioninsights.ai/#organization",
"@type": "Organization",
"contactPoint": {
"@type": "ContactPoint",
"contactType": "customer support",
"email": "[email protected]"
},
"description": "Decision Insights is a Registry of technology companies, open source projects, and industry terms, built for people and for AI agents that need sourced, structured information.",
"legalName": "Wiretap Labs, LLC",
"logo": {
"@type": "ImageObject",
"url": "https://wiretap-cdn-assets.nyc3.cdn.digitaloceanspaces.com/decision-insights/[email protected]"
},
"name": "Decision Insights",
"parentOrganization": {
"@type": "Organization",
"name": "Wiretap Labs",
"sameAs": [
"https://www.linkedin.com/company/wiretap-labs",
"https://www.crunchbase.com/organization/wiretap-labs"
],
"url": "https://wiretaplabs.com"
},
"publishingPrinciples": "https://decisioninsights.ai/standards/",
"sameAs": [
"https://www.linkedin.com/company/decisioninsights"
],
"subjectOf": {
"@type": "WebPage",
"name": "Agent Ready status of decisioninsights.ai, checked by Stringer",
"url": "https://stringer.ai/agent-ready/decisioninsights.ai/"
},
"url": "https://decisioninsights.ai"
},
{
"@context": "https://schema.org",
"@type": "BreadcrumbList",
"itemListElement": [
{
"@type": "ListItem",
"item": "https://decisioninsights.ai",
"name": "Decision Insights",
"position": 1
},
{
"@type": "ListItem",
"item": "https://decisioninsights.ai/term/",
"name": "Glossary",
"position": 2
},
{
"@type": "ListItem",
"item": "https://decisioninsights.ai/term/phasor-measurement-unit-pmu/",
"name": "Phasor Measurement Unit",
"position": 3
}
]
},
{
"@context": "https://schema.org",
"@id": "https://decisioninsights.ai/term/phasor-measurement-unit-pmu/#definedterm",
"@type": "DefinedTerm",
"additionalProperty": [
{
"@type": "PropertyValue",
"name": "Related terms",
"valueReference": [
{
"@id": "https://decisioninsights.ai/term/power-conditioning-unit-pcu/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-conditioning-unit-pcu/",
"name": "Power Conditioning Unit"
},
{
"@id": "https://decisioninsights.ai/term/power-management-system-pms/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-management-system-pms/",
"name": "Power Management System"
},
{
"@id": "https://decisioninsights.ai/term/power-quality-monitoring/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-quality-monitoring/",
"name": "Power Quality Monitoring"
},
{
"@id": "https://decisioninsights.ai/term/power-monitoring/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-monitoring/",
"name": "Power Monitoring"
},
{
"@id": "https://decisioninsights.ai/term/power-distribution-unit-pdu/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-distribution-unit-pdu/",
"name": "Power Distribution Unit"
},
{
"@id": "https://decisioninsights.ai/term/power-analyzer-pa/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-analyzer-pa/",
"name": "Power Analyzer"
},
{
"@id": "https://decisioninsights.ai/term/power-usage-effectiveness-pue-monitor/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-usage-effectiveness-pue-monitor/",
"name": "Power Usage Effectiveness (PUE) Monitor"
},
{
"@id": "https://decisioninsights.ai/term/inertial-measurement-unit-imu/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/inertial-measurement-unit-imu/",
"name": "Inertial Measurement Unit"
}
]
}
],
"description": "Phasor measurement unit is a time-synchronized measurement device in electric power systems that captures voltage and current phasors, frequency, and related quantities, enabling wide-area monitoring, control, and analysis that rely on precise, geographically distributed grid visibility for reliable operations and planning.",
"inDefinedTermSet": {
"@id": "https://decisioninsights.ai/term/#termset",
"@type": "DefinedTermSet",
"url": "https://decisioninsights.ai/term/"
},
"name": "Phasor Measurement Unit",
"termCode": "PMU",
"url": "https://decisioninsights.ai/term/phasor-measurement-unit-pmu/"
},
{
"@context": "https://schema.org",
"@id": "https://decisioninsights.ai/term/phasor-measurement-unit-pmu/",
"@type": "CollectionPage",
"dateModified": "2026-08-24T03:06:24Z",
"description": "Phasor measurement unit is a time-synchronized measurement device in electric power systems that captures voltage and current phasors, frequency, and related quantities, enabling wide-area monitoring, control, and analysis that rely on precise, geographically distributed grid visibility for reliable operations and planning.",
"isPartOf": {
"@id": "https://decisioninsights.ai/#website"
},
"mainEntity": {
"@id": "https://decisioninsights.ai/term/phasor-measurement-unit-pmu/#definedterm"
},
"name": "Phasor Measurement Unit",
"sdDatePublished": "2026-08-24",
"sdPublisher": {
"@id": "https://decisioninsights.ai/#organization"
},
"url": "https://decisioninsights.ai/term/phasor-measurement-unit-pmu/"
},
{
"@context": "https://schema.org",
"@type": "FAQPage",
"mainEntity": [
{
"@type": "Question",
"acceptedAnswer": {
"@type": "Answer",
"text": "A Phasor Measurement Unit (PMU) is a time-synchronized device in electric power systems that measures voltage and current phasors, frequency, and rate of change of frequency using a precise time reference, typically GPS, for high-speed wide-area monitoring and control.\nExpanded Explanation\n1. Technical Function and Core Characteristics\nA PMU measures synchronized voltage and current phasors at substations or generation sites and time-stamps them using a common reference such as GPS. It samples"
},
"name": "What is Phasor Measurement Unit?"
}
]
}
]Is this your company? Get structured data for your own pages
The CLI command and the REST call for this record need a free account: run di login, or send your OAuth token. Over MCP it is free with none.
How an agent can rely on this definition
What the record lets an agent check before it uses the term in an answer.
| The check | What the record shows | Where it is in the data |
|---|---|---|
| It's a known term | One entry, with its abbreviation and type (topic) | name, alternateName |
| It sits in a glossary | Linked to Power Conditioning Unit, Power Management System, Power Quality Monitoring, Power Monitoring | inDefinedTermSet |
View the raw record (JSON-LD)
[
{
"@context": "https://schema.org",
"@id": "https://decisioninsights.ai/#website",
"@type": "WebSite",
"name": "Decision Insights",
"potentialAction": {
"@type": "SearchAction",
"target": {
"@type": "EntryPoint",
"urlTemplate": "https://decisioninsights.ai/search/?q={search_term_string}&submit=1"
}
},
"publisher": {
"@id": "https://decisioninsights.ai/#organization"
},
"url": "https://decisioninsights.ai"
},
{
"@context": "https://schema.org",
"@id": "https://decisioninsights.ai/#organization",
"@type": "Organization",
"contactPoint": {
"@type": "ContactPoint",
"contactType": "customer support",
"email": "[email protected]"
},
"description": "Decision Insights is a Registry of technology companies, open source projects, and industry terms, built for people and for AI agents that need sourced, structured information.",
"legalName": "Wiretap Labs, LLC",
"logo": {
"@type": "ImageObject",
"url": "https://wiretap-cdn-assets.nyc3.cdn.digitaloceanspaces.com/decision-insights/[email protected]"
},
"name": "Decision Insights",
"parentOrganization": {
"@type": "Organization",
"name": "Wiretap Labs",
"sameAs": [
"https://www.linkedin.com/company/wiretap-labs",
"https://www.crunchbase.com/organization/wiretap-labs"
],
"url": "https://wiretaplabs.com"
},
"publishingPrinciples": "https://decisioninsights.ai/standards/",
"sameAs": [
"https://www.linkedin.com/company/decisioninsights"
],
"subjectOf": {
"@type": "WebPage",
"name": "Agent Ready status of decisioninsights.ai, checked by Stringer",
"url": "https://stringer.ai/agent-ready/decisioninsights.ai/"
},
"url": "https://decisioninsights.ai"
},
{
"@context": "https://schema.org",
"@type": "BreadcrumbList",
"itemListElement": [
{
"@type": "ListItem",
"item": "https://decisioninsights.ai",
"name": "Decision Insights",
"position": 1
},
{
"@type": "ListItem",
"item": "https://decisioninsights.ai/term/",
"name": "Glossary",
"position": 2
},
{
"@type": "ListItem",
"item": "https://decisioninsights.ai/term/phasor-measurement-unit-pmu/",
"name": "Phasor Measurement Unit",
"position": 3
}
]
},
{
"@context": "https://schema.org",
"@id": "https://decisioninsights.ai/term/phasor-measurement-unit-pmu/#definedterm",
"@type": "DefinedTerm",
"additionalProperty": [
{
"@type": "PropertyValue",
"name": "Related terms",
"valueReference": [
{
"@id": "https://decisioninsights.ai/term/power-conditioning-unit-pcu/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-conditioning-unit-pcu/",
"name": "Power Conditioning Unit"
},
{
"@id": "https://decisioninsights.ai/term/power-management-system-pms/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-management-system-pms/",
"name": "Power Management System"
},
{
"@id": "https://decisioninsights.ai/term/power-quality-monitoring/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-quality-monitoring/",
"name": "Power Quality Monitoring"
},
{
"@id": "https://decisioninsights.ai/term/power-monitoring/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-monitoring/",
"name": "Power Monitoring"
},
{
"@id": "https://decisioninsights.ai/term/power-distribution-unit-pdu/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-distribution-unit-pdu/",
"name": "Power Distribution Unit"
},
{
"@id": "https://decisioninsights.ai/term/power-analyzer-pa/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-analyzer-pa/",
"name": "Power Analyzer"
},
{
"@id": "https://decisioninsights.ai/term/power-usage-effectiveness-pue-monitor/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/power-usage-effectiveness-pue-monitor/",
"name": "Power Usage Effectiveness (PUE) Monitor"
},
{
"@id": "https://decisioninsights.ai/term/inertial-measurement-unit-imu/#definedterm",
"@type": "DefinedTerm",
"mainEntityOfPage": "https://decisioninsights.ai/term/inertial-measurement-unit-imu/",
"name": "Inertial Measurement Unit"
}
]
}
],
"description": "Phasor measurement unit is a time-synchronized measurement device in electric power systems that captures voltage and current phasors, frequency, and related quantities, enabling wide-area monitoring, control, and analysis that rely on precise, geographically distributed grid visibility for reliable operations and planning.",
"inDefinedTermSet": {
"@id": "https://decisioninsights.ai/term/#termset",
"@type": "DefinedTermSet",
"url": "https://decisioninsights.ai/term/"
},
"name": "Phasor Measurement Unit",
"termCode": "PMU",
"url": "https://decisioninsights.ai/term/phasor-measurement-unit-pmu/"
},
{
"@context": "https://schema.org",
"@id": "https://decisioninsights.ai/term/phasor-measurement-unit-pmu/",
"@type": "CollectionPage",
"dateModified": "2026-08-24T03:06:24Z",
"description": "Phasor measurement unit is a time-synchronized measurement device in electric power systems that captures voltage and current phasors, frequency, and related quantities, enabling wide-area monitoring, control, and analysis that rely on precise, geographically distributed grid visibility for reliable operations and planning.",
"isPartOf": {
"@id": "https://decisioninsights.ai/#website"
},
"mainEntity": {
"@id": "https://decisioninsights.ai/term/phasor-measurement-unit-pmu/#definedterm"
},
"name": "Phasor Measurement Unit",
"sdDatePublished": "2026-08-24",
"sdPublisher": {
"@id": "https://decisioninsights.ai/#organization"
},
"url": "https://decisioninsights.ai/term/phasor-measurement-unit-pmu/"
},
{
"@context": "https://schema.org",
"@type": "FAQPage",
"mainEntity": [
{
"@type": "Question",
"acceptedAnswer": {
"@type": "Answer",
"text": "A Phasor Measurement Unit (PMU) is a time-synchronized device in electric power systems that measures voltage and current phasors, frequency, and rate of change of frequency using a precise time reference, typically GPS, for high-speed wide-area monitoring and control.\nExpanded Explanation\n1. Technical Function and Core Characteristics\nA PMU measures synchronized voltage and current phasors at substations or generation sites and time-stamps them using a common reference such as GPS. It samples"
},
"name": "What is Phasor Measurement Unit?"
}
]
}
]